Apartment ceiling leak traced by thermal imaging

A homeowner had been quoted for a full bathroom demolition to fix a damp bedroom ceiling. The thermal survey showed the bathroom was not the source.

Area
1,450 sq.ft flat
Duration
4 days
Sector
Residential
Location
Anna Nagar, Chennai
System
Thermal survey + concealed pipeline repair + localised waterproofing
Thermal image tracing a concealed hot water pipeline leak behind a bathroom wall
Start to finish
4 daysStart to finish
Wall opening needed
1Wall opening needed
Bathrooms demolished
0Bathrooms demolished

The problem

A persistent damp patch on a bedroom ceiling had been growing for eight months. Two contractors had quoted to break out and re-waterproof the entire bathroom of the flat above — a disruptive job running into weeks of the upstairs neighbour's bathroom being unusable.

The diagnosis

The infrared survey showed the bathroom sunken slab was dry. The moisture signature traced back to a warm linear plume running through the shaft wall — a concealed hot water supply line on the floor above the bathroom, leaking at a joint and running down inside the shaft before spreading across the bedroom slab.

What we did

  1. 1Non-destructive thermal survey of the affected flat and the two flats above
  2. 2Confirmed the source with moisture-meter readings at the shaft wall
  3. 3Opened a single 600 mm section of shaft wall — not the bathroom
  4. 4Replaced the failed pipe joint and pressure-tested the line
  5. 5Treated the affected slab area and made good the shaft wall and ceiling
  6. 6Verification thermal scan after seven days of drying

The result

Resolved in four days without touching the bathroom, at a fraction of the demolition quotes the owner had received. The ceiling was repainted once the slab had fully dried.

Before & after

Drag to compare

Thermal image identifying the concealed pipeline as the true leak source
Thermal scan of the affected bedroom ceiling slab showing the moisture plume
BeforeAfter
Thermal diagnosis — the stain and the source were four metres apart