Factory corporate office terrace — mesh waterproofing

A factory corporate office block had recurring ceiling seepage across the top floor after every monsoon. Two previous contractors had recoated the terrace without success.

Area
12,000 sq.ft
Duration
9 days
Sector
Industrial
Location
Avadi, Chennai
System
Mesh-reinforced acrylic membrane with slope correction
Mesh-reinforced acrylic waterproofing membrane being applied on a factory terrace in Avadi
Leaks since handover
0Leaks since handover
Monsoons clear
2Monsoons clear
Written warranty
10 yrWritten warranty

The problem

Water was appearing on the top-floor ceiling in multiple rooms during heavy rain, staining false ceilings and creating an electrical risk around light fittings. The terrace had been coated twice in four years by other contractors and the problem returned each monsoon.

The diagnosis

A thermal imaging survey showed moisture concentrated along two lines that did not correspond to the visible ceiling stains at all — the water was entering at shrinkage cracks near the parapet junction and travelling laterally along the slab before appearing several metres away. Ponding marks confirmed a dead slope with no fall toward two of the four outlets.

What we did

  1. 1Removed the two failed coating layers back to sound concrete
  2. 2Opened and filled shrinkage cracks with polymer-modified compound in V-grooves
  3. 3Re-screeded the deck to establish fall toward all four rainwater outlets
  4. 4Rebuilt parapet junction fillets and drain khurras
  5. 5Applied mesh-reinforced acrylic membrane — fibreglass mesh embedded between elastomeric coats to bridge future movement
  6. 6Wet test held for 48 hours, followed by a verification thermal scan

The result

No leakage reported through two subsequent Chennai monsoons, including the heavy north-east monsoon. The client has since engaged us for two further buildings on the same campus.

“They did terrace area mesh waterproofing at our factory corporate office building last year. There's no leakage found in past Chennai heavy rain and no seepage inside the wall and ceiling area. Very technical expertise in construction and building care, well execution of work.”
— Fayaz Rahman

Before & after

Drag to compare

Completed mesh-reinforced waterproofing membrane on the factory terrace
Factory terrace before treatment showing ponding and screed correction work in progress
BeforeAfter
Slope correction and membrane application — Avadi factory terrace
CallWhatsAppFree Quote
Call NowWhatsApp